Internal Copper Telecom Cable Archives - Ò»Æð²Ý /product-category/internal-copper-telecom-cable/ Wed, 30 Nov 2022 18:04:27 +0000 en-GB hourly 1 https://wordpress.org/?v=7.0 /wp-content/uploads/2023/01/cropped-BCCfav-32x32.png Internal Copper Telecom Cable Archives - Ò»Æð²Ý /product-category/internal-copper-telecom-cable/ 32 32 Wire Connector 12000 /product/wire-connector-12000/ Fri, 18 Nov 2022 17:26:28 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=1765 Tinned Annealed Copper Wire / Polyvinyl Chloride Insulation (Complies with BT Specification CW1321 Ò»Æð²Ý – Wire Connector 12000) Application This product is robust PVC insulated tinned copper annealed wire, available as a single wire, a twisted pair, twisted triple, twisted quad or twisted quintuple. It is intended for use with Insulation Displacement Connectors (IDC) when they

The post Wire Connector 12000 appeared first on Ò»Æð²Ý.

]]>
Tinned Annealed Copper Wire / Polyvinyl Chloride Insulation

(Complies with BT Specification CW1321 Ò»Æð²Ý – Wire Connector 12000)

Application

This product is robust PVC insulated tinned copper annealed wire, available as a single wire, a twisted pair, twisted triple, twisted quad or twisted quintuple. It is intended for use with Insulation Displacement Connectors (IDC) when they are fitted to distribution frames in customer premises.

The post Wire Connector 12000 appeared first on Ò»Æð²Ý.

]]>
CW1308B Internal / External LSZH Cable /product/cw1308b-internal-external-lszh-cable/ Tue, 01 Nov 2022 12:34:05 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=232 CW1308B Indoor Outdoor Campus Cables (Construction and Electrical Performance as per BT Specification CW1308) Indoor / Outdoor Cable PACW / PVC Insulation / Moisture Barrier / HFFR Sheathed   Application The cable is designed primarily for interconnection between buildings within a telecommunication network where the cable is used both inside the building and outside in

The post CW1308B Internal / External LSZH Cable appeared first on Ò»Æð²Ý.

]]>
CW1308B Indoor Outdoor Campus Cables

(Construction and Electrical Performance as per BT Specification CW1308)

Indoor / Outdoor Cable
PACW / PVC Insulation / Moisture Barrier / HFFR Sheathed

 

Application

The cable is designed primarily for interconnection between buildings within a telecommunication network where the cable is used both inside the building and outside in ducts between the buildings. The cable replaces the traditional PVC sheathed cable inside the building and the Polyethylene sheathed cable outside, making the need to joint at building entries redundant. The design includes a metallic moisture barrier bonded to the sheath to combat the ingress of moisture vapour and the sheath is a low smoke non-halogenated polymer, which imparts a high degree of flame retardancy to the cable. The cable core is similar to BT Specification CW 1308.

Construction

Twisted pairs in 10 Pair Units. The pair range is 10 Ò»Æð²Ý – 100.

Cable Description
  • Plain annealed solid copper wire
  • PVC insulation with the required number of pairs assembled in 20 pair units
  • A polyester tape is applied over the cable core followed by a Polyethylene/Aluminium Laminate moisture barrier, which is bonded to the Low Smoke Non-Halogenated (HFFR) sheath.
  • An optional 1.38mm diameter PVC insulated Earth Wire may be included within the cable core upon request

The post CW1308B Internal / External LSZH Cable appeared first on Ò»Æð²Ý.

]]>
CW1600 Internal LSZH Limited Fire Hazard Cable /product/cw1600-internal-lszh-limited-fire-hazard-cable/ Tue, 01 Nov 2022 12:34:05 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=234 Internal Telephony Wiring – High Fire Retardancy (Complies with BT Specification CW1600) PACW / PE / Foil Screen / HFFR Sheathed   Application Designed for use internally where there is a risk of fire. This cable is compliant with BS6701:2016+A1:2017: Telecommunications equipment and telecommunications cabling specification for installation, operation and maintenance, with a minimum CPR

The post CW1600 Internal LSZH Limited Fire Hazard Cable appeared first on Ò»Æð²Ý.

]]>
Internal Telephony Wiring – High Fire Retardancy

(Complies with BT Specification CW1600)

PACW / PE / Foil Screen / HFFR Sheathed

 

Application

Designed for use internally where there is a risk of fire. This cable is compliant with BS6701:2016+A1:2017: Telecommunications equipment and telecommunications cabling specification for installation, operation and maintenance, with a minimum CPR classification of Cca (s1b, d2, a2).

The cable is designed to handle low frequency signals and is intended to be terminated in Insulation Displacement Connectors (IDC), but may be soldered or wrapped. The cable is intended to take the place of Polyvinyl Chloride (PVC) sheathed cables and will withstand similar environments with a similar working life.

Cable Description
  • Plain annealed solid copper wire
  • Polyethylene insulated twisted pair
  • Continuity wire
  • Metalised polyester screen
  • Fire retardant tape
  • HFFR sheath

N.B. In the event of fire, the gases evolved from this cable are free from Halogen and the design is optimised to limit the quantity and cleanliness of the smoke evolved during this period. Although the acronym HFFR is applied to the sheath material, the terms LSOH, HFFR and HFFR are also applicable.

The post CW1600 Internal LSZH Limited Fire Hazard Cable appeared first on Ò»Æð²Ý.

]]>
CW1308 Internal PVC Cable /product/cw1308-internal-pvc-cable/ Thu, 06 Oct 2022 12:31:00 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=228 Internal Telephony Wiring – PVC/PVC (Complies with BT Specification CW1308) Central Office Cable Plain Annealed Copper Wire/PVC Insulation/PVC Sheathed   Application The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation. Displacement Connectors (IDC), but may be soldered or wrapped. Construction There are three modes

The post CW1308 Internal PVC Cable appeared first on Ò»Æð²Ý.

]]>
Internal Telephony Wiring – PVC/PVC

(Complies with BT Specification CW1308)

Central Office Cable
Plain Annealed Copper Wire/PVC Insulation/PVC Sheathed

 

Application

The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation. Displacement Connectors (IDC), but may be soldered or wrapped.

Construction

There are three modes of construction; Layer for general use, including two cables for installation in customerÒ»Æð²Ý ’s premises where a good appearance is required. Unit, of 20 pairs, including a 1.38mm diameter insulated earth conductor, for use with customer distribution schemes. Unit, of 16 pairs, for use with the binary number system. Unit, of 30 pairs, for use with Pulse Code Modulation (PCM) systems.

Cable Description
  • Plain annealed solid copper wire
  • PVC insulated twisted pair or triple
  • PVC sheath
  • An optional screen of aluminium/PVC is available on request

The post CW1308 Internal PVC Cable appeared first on Ò»Æð²Ý.

]]>
Jumper Wire Series 9000 /product/jumperwire/ Thu, 06 Oct 2022 12:30:00 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=220 Plain Annealed Copper Wire / Polyvinyl Chloride Insulation (Complies with BT Specification CW1423) Application This product is a robust PVC insulated plain copper annealed wire, available as a single wire or twisted pair. It is designed primarily for jumpering or hook up on distribution frames and is also used as a general equipment wire in

The post Jumper Wire Series 9000 appeared first on Ò»Æð²Ý.

]]>
Plain Annealed Copper Wire / Polyvinyl Chloride Insulation

(Complies with BT Specification CW1423)

Application

This product is a robust PVC insulated plain copper annealed wire, available as a single wire or twisted pair. It is designed primarily for jumpering or hook up on distribution frames and is also used as a general equipment wire in cabinets and exchange equipment.

The post Jumper Wire Series 9000 appeared first on Ò»Æð²Ý.

]]>
CW1308 Internal LSZH Cable /product/cw1308-internal-lszh-cable/ Thu, 06 Oct 2022 12:25:00 +0000 http://britishcablescompany-com.stackstaging.com/?post_type=bcc-product&p=230 Internal Telephony Wiring – PVC/HFFR (Generally Complies with BT Specification CW1308) Central Office Cable Plain Annealed Copper Wire/PVC Insulation/HFFR Sheathed   Application The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation. Displacement Connectors (IDC), but may be soldered or wrapped. Construction There are three

The post CW1308 Internal LSZH Cable appeared first on Ò»Æð²Ý.

]]>
Internal Telephony Wiring – PVC/HFFR

(Generally Complies with BT Specification CW1308)

Central Office Cable
Plain Annealed Copper Wire/PVC Insulation/HFFR Sheathed

 

Application

The cable is designed to handle low frequency signals for short-range applications and is intended to be terminated in Insulation. Displacement Connectors (IDC), but may be soldered or wrapped.

Construction

There are three modes of construction; Layer for general use, including two cables for installation in customerÒ»Æð²Ý ’s premises where a good appearance is required. Unit, of 20 pairs, including a 1.38mm diameter insulated earth conductor, for use with customer distribution schemes. Unit, of 16 pairs, for use with the binary number system. Unit, of 30 pairs, for use with Pulse Code Modulation (PCM) systems.

Cable Description
  • Plain annealed solid copper wire
  • PVC insulated twisted pair or triple
  • HFFR sheath
  • An optional collective screen of aluminium coated polyester is available on request

The post CW1308 Internal LSZH Cable appeared first on Ò»Æð²Ý.

]]>